Human Tumor Necrosis Factor Related Apoptosis Inducing Ligand (TRAIL) ELISA Kit (CLIA)
Size
96 TestsCatalog no#
EKU08846Price
1032 EURTissue
tumor
Shipping Conditions
Ice packs
Sensitivity
15.5 pg/mL
Detection Range
41.2-30000 pg/mL
Detection Method
Chemiluminescent
Estimated Turnaround Time
6-11 Business days
Assay Time
2 hours, 40minutes
Species Reactivity
Homo sapiens (Human)
Assay Type
Double-antibody Sandwich
Research Area
Apoptosis, Tumor immunity
Storage Temperature
Short term: 4°C; Long term: see manual.
Application
For research use only. Not for diagnostic procedures.
Target Name
Tumor Necrosis Factor Related Apoptosis Inducing Ligand
Test
ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED
Precaution of Use
The Stop Solution is acidic. Do not allow to contact skin or eyes.
Quality Systems
The kit is manufactured at ISO 9001 and ISO 13485 certified facilities.
Sample Type
Serum, Plasma, Tissue homogenates, Cell lysates, Cell culture supernates and other biological fluids
Shelf life
Use Human Tumor Necrosis Factor Related Apoptosis Inducing Ligand (TRAIL) ELISA Kit (CLIA) before 8 months
Target's alterntive name
CD253, TNFSF10, APO2L, Apo2-L, TL2, TRAIL, Tumor Necrosis Factor Ligand Superfamily Member 10, Apo-2 Ligand
Specificity
This assay has high sensitivity and excellent specificity for detection of Tumor Necrosis Factor Related Apoptosis Inducing Ligand
Cross Activity
No significant cross-reactivity or interference between Tumor Necrosis Factor Related Apoptosis Inducing Ligand and analogues was observed.
Test Principle
No significant cross-reactivity or interference between Tumor Necrosis Factor Related Apoptosis Inducing Ligand and analogues was observed.
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Tumor Necrosis Factor Related Apoptosis Inducing Ligand were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Tumor Necrosis Factor Related Apoptosis Inducing Ligand were tested on 3 different plates, 8 replicates in each plate.CV (%) = SD/meanX100;Intra-Assay: CV
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Properties
E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,Human proteins, cDNA and human recombinants are used in human reactive ELISA kits and to produce anti-human mono and polyclonal antibodies. Modern humans (Homo sapiens, primarily ssp. Homo sapiens sapiens). Depending on the epitopes used human ELISA kits can be cross reactive to many other species. Mainly analyzed are human serum, plasma, urine, saliva, human cell culture supernatants and biological samples.
Description
This 1 is suited for programmed cell-death studies.Aplha, transcription related growth factors and stimulating factors or repressing nuclear factors are complex subunits of proteins involved in cell differentiation. Complex subunit associated factors are involved in hybridoma growth, Eosinohils, eritroid proliferation and derived from promotor binding stimulating subunits on the DNA binding complex. NFKB 105 subunit for example is a polypetide gene enhancer of genes in B cells.FAS ligand and other ligands are binding to the receptor for signaling pathways for example in apoptosis or JNK signaling. Receptor agonists are often tested for drug development.