Rat p53 Upregulated Modulator Of Apoptosis (PUMA) ELISA Kit
Size
96 TestsCatalog no#
EKU06459Price
908 EURAssay Time
3 hours
Sensitivity
5.4 pg/mL
Shipping Conditions
Ice packs
Detection Method
Colorimetric
Detection Range
15.6-1000 pg/mL
Latin name
Rattus norvegicus
Estimated Turnaround Time
6-11 Business days
Species Reactivity
Rattus norvegicus (Rat)
Assay Type
Double-antibody Sandwich
Research Area
Apoptosis, Tumor immunity
Target's alterntive name
JFY1, BBC3, BCL2 Binding Component 3
Target Name
p53 Upregulated Modulator Of Apoptosis
Storage Temperature
Short term: 4°C; Long term: see manual.
Description
This 1 is suited for programmed cell-death studies.
Application
For research use only. Not for diagnostic procedures.
Sample Type
Tissue homogenates, Cell lysates and other biological fluids
Test
ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED
Precaution of Use
The Stop Solution is acidic. Do not allow to contact skin or eyes.
Quality Systems
The kit is manufactured at ISO 9001 and ISO 13485 certified facilities.
Shelf life
Use Rat p53 Upregulated Modulator Of Apoptosis (PUMA) ELISA Kit before 8 months
Specificity
This assay has high sensitivity and excellent specificity for detection of p53 Upregulated Modulator Of Apoptosis
Properties
E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays
Cross Activity
No significant cross-reactivity or interference between p53 Upregulated Modulator Of Apoptosis and analogues was observed.
Test Principle
No significant cross-reactivity or interference between p53 Upregulated Modulator Of Apoptosis and analogues was observed.
About
Rats are used to make rat monoclonal anti mouse antibodies. There are less rat- than mouse clones however. Rats genes from rodents of the genus Rattus norvegicus are often studied in vivo as a model of human genes in Sprague-Dawley or Wistar rats.
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level p53 Upregulated Modulator Of Apoptosis were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level p53 Upregulated Modulator Of Apoptosis were tested on 3 different plates, 8 replicates in each plate.CV (%) = SD/meanX100;Intra-Assay: CV
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.